[PATCH] x86_64: Explain why HPET T0_CMP register is written twice

After writing the CFG register, the first value written to the T0_CMP
register is the value at which next interrupt should be triggered, every
value after that sets the period of the interrupt. For that reason, the code
needs to write the value twice - to set both the phase and period.

[AK: I had already figured it out by myself, but it's still useful
to have a comment for this.]

Signed-off-by: Vojtech Pavlik <vojtech@suse.cz>
Signed-off-by: Andi Kleen <ak@suse.de>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
This commit is contained in:
Vojtech Pavlik 2006-06-26 13:58:35 +02:00 committed by Linus Torvalds
parent 4221133845
commit b2df3ddb68

View file

@ -795,8 +795,8 @@ static int hpet_timer_stop_set_go(unsigned long tick)
if (hpet_use_timer) {
hpet_writel(HPET_TN_ENABLE | HPET_TN_PERIODIC | HPET_TN_SETVAL |
HPET_TN_32BIT, HPET_T0_CFG);
hpet_writel(hpet_tick, HPET_T0_CMP);
hpet_writel(hpet_tick, HPET_T0_CMP); /* AK: why twice? */
hpet_writel(hpet_tick, HPET_T0_CMP); /* next interrupt */
hpet_writel(hpet_tick, HPET_T0_CMP); /* period */
cfg |= HPET_CFG_LEGACY;
}
/*