IB/mlx4: Unregister IB device prior to CLOSE PORT command

According to the ConnectX programmer's reference manual, all
operations should be stopped, all QPs should be torn down and all WQEs
flushed before the CLOSE_PORT command is invoked.  In some cases
reversing the order of operations (as implemented now) could cause
a loss of completions.

Signed-off-by: Yevgeny Petrilin <yevgenyp@mellanox.co.il>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
This commit is contained in:
Yevgeny Petrilin 2009-03-18 19:49:54 -07:00 committed by Roland Dreier
parent 27bf91d6a0
commit a6a47771b1

View file

@ -699,11 +699,12 @@ static void mlx4_ib_remove(struct mlx4_dev *dev, void *ibdev_ptr)
struct mlx4_ib_dev *ibdev = ibdev_ptr;
int p;
mlx4_ib_mad_cleanup(ibdev);
ib_unregister_device(&ibdev->ib_dev);
for (p = 1; p <= ibdev->num_ports; ++p)
mlx4_CLOSE_PORT(dev, p);
mlx4_ib_mad_cleanup(ibdev);
ib_unregister_device(&ibdev->ib_dev);
iounmap(ibdev->uar_map);
mlx4_uar_free(dev, &ibdev->priv_uar);
mlx4_pd_free(dev, ibdev->priv_pdn);