cfg80211: allow setting station parameters in mesh

Mesh Point interfaces can also set parameters, for example plink_open is
used to manually establish peer links from user-space (currently via
iw).  Add Mesh Point to the check in nl80211_set_station.

Signed-off-by: Andrey Yurovsky <andrey@cozybit.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Andrey Yurovsky 2009-06-16 16:09:37 -07:00 committed by John W. Linville
parent 155cc9e4b1
commit 9a5e8bbc8f

View file

@ -1688,7 +1688,8 @@ static int nl80211_set_station(struct sk_buff *skb, struct genl_info *info)
goto out_rtnl;
if (dev->ieee80211_ptr->iftype != NL80211_IFTYPE_AP &&
dev->ieee80211_ptr->iftype != NL80211_IFTYPE_AP_VLAN) {
dev->ieee80211_ptr->iftype != NL80211_IFTYPE_AP_VLAN &&
dev->ieee80211_ptr->iftype != NL80211_IFTYPE_MESH_POINT) {
err = -EINVAL;
goto out;
}