mirror of
https://github.com/adulau/aha.git
synced 2025-01-03 22:53:18 +00:00
[ALSA] pcxhr - Fix the sample rate changes
Modules: Digigram PCXHR driver Fix the hardware set up when the sample rate is changed multiple times. Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
parent
d298139361
commit
8937fd8855
1 changed files with 4 additions and 3 deletions
|
@ -744,13 +744,14 @@ static int pcxhr_prepare(struct snd_pcm_substream *subs)
|
||||||
/* only the first stream can choose the sample rate */
|
/* only the first stream can choose the sample rate */
|
||||||
/* the further opened streams will be limited to its frequency (see open) */
|
/* the further opened streams will be limited to its frequency (see open) */
|
||||||
/* set the clock only once (first stream) */
|
/* set the clock only once (first stream) */
|
||||||
if (mgr->sample_rate == 0) {
|
if (mgr->sample_rate != subs->runtime->rate) {
|
||||||
err = pcxhr_set_clock(mgr, subs->runtime->rate);
|
err = pcxhr_set_clock(mgr, subs->runtime->rate);
|
||||||
if (err)
|
if (err)
|
||||||
break;
|
break;
|
||||||
|
if (mgr->sample_rate == 0)
|
||||||
|
/* start the DSP-timer */
|
||||||
|
err = pcxhr_hardware_timer(mgr, 1);
|
||||||
mgr->sample_rate = subs->runtime->rate;
|
mgr->sample_rate = subs->runtime->rate;
|
||||||
|
|
||||||
err = pcxhr_hardware_timer(mgr, 1); /* start the DSP-timer */
|
|
||||||
}
|
}
|
||||||
} while(0); /* do only once (so we can use break instead of goto) */
|
} while(0); /* do only once (so we can use break instead of goto) */
|
||||||
|
|
||||||
|
|
Loading…
Reference in a new issue